Use APKPure App
Get Modbus Monitor Advanced old version APK for Android
Modbus Client and Server with TCP/IP, Bluetooth, or Serial Ports
Learn Modbus with full protocol stacks, or get all data from your remote Modbus RTU devices by defining your full modbus map, or use your mobile devcie to simulate Modbus devices or sensors.
This Modbus App has three Apps in one:
(1) Modbus Client (Master)
(2) Modbus Server (Slave)
(3) Modbus TCP Sensors Server
Four Interfaces:
(1) Bluetooth SPP & BLE
(2) Ethernet
(3) Wi-Fi
(4) RS232/485 USB Serial ports via USB OTG
Eight Protocols to choose from:
(1) Modbus TCP
(2) Enron/Daniels TCP
(3) Modbus RTU over TCP
(4) Modbus UDP
(5) Modbus RTU over UDP
(6) Modbus TCP Slave/Server
(7) Modbus RTU
(8) Modbus Serial ASCII
Push data to cloud:
> MQTT
> Google Sheets
> ThinkSpeak
Sensor Server:
Explore Sensor Server: Remotely monitor mobile device's sensors using Modbus Protocols
Import/Export:
Import in CSV format. Export data to CSV format every second, minute, or hour. Export configuration data via email or log to ThinkSpeak or Google Sheets Cloud platforms
About Modbus Support
(1) Modbus Functions: FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, Write Auto
(2) Simple 6 digit Input Modbus Address input (4x, 3x, 1x, 0x)
(3) Data Conversion: Unsigned, Signed, Hex, Binary, Long, Double, Float, String, BCD formats, Unix Epoch Time, PLC Scaling (Bipolar/Unipolar Analog ADC value conversion)
(4) Convert Modbus Integer Values to Text (Coded Message or Status Converter)
(5) Push to write pre-set value
Pro-Turning Options
Interval, Inter-Packet Delay, Link-Timeout, Actual RX/TX Counts
Bluetooth Requirements:
(1) Your device must have Bluetooth Radio that supports SPP profile (RFCOMM Secure or Insecure)
(2) See "ModbusMonitor.com" or email [email protected] for help
(3) See below for hardware requirements
USB-OTG Serial Ports Requirements:
(1) Your device must be Android version 3.2 or newer
(2) Your device must support USB Host or OTG interface
(3) Your USB-to-Serial Port dongle must contain one of following chipsets: >FTDI [FT230X, FT231X, FT234XD, FT232R, or FT232H], Prolific [PL2303HXD, PL2303EA, or PL2303RA], SiLab [CP210x], QinHeng CH34x
(4) RS485: Tested with "no echo" setting turned ON.
Feedback
www.ModbusMonitor.com contains an online form in the "Feeback" section for those interested in providing constructive feedback or feature requests.
Last updated on May 3, 2020
2017-05-10
(NEW) Added Ch34x based USB Serial Ports Support
(NEW) Long-press Mobus Item to write pre-set values (Similar to Write value on Button Push)
(NEW) Log Polled data in Google Spreadsheet in your own account ***
(New) Coded Message (Convert Modbus Values to Custom Text)
(New) Added additional sensors to Modbus Server (Cellphone MNC, MCC, CID, LAC, Signal Strength, Network Type, Cell Tower Location, Cell Tower ID, Cell Tower Location,
(New) Export Data at regular timer interval (>1min)
Uploaded by
Mahar Myanmar
Requires Android
5.0
Category
Report
Modbus Monitor Advanced
6.0.0 by Quantum Bit Solutions
Oct 29, 2023
$1.99